Close
Sonde différentielle 70 MHz : TT-SI 9071 Agrandir l'image

Sonde différentielle 70 MHz : TT-SI 9071 | TESTEC ELEKTRONIK

Bandwidth DC to 70 MHz (-3 dB) Attenuation Ratio x10 / x100 DC-Accuracy ±1 % Input Impedance 4 MΩ, 5.5 pF each side to ground Rise Time 5 ns Measurement Category CAT III Max. Amplitude ±7 V (into < 5 kΩ load) Offset <±5 mV Noise (typical) 2...

Téléchargez GRATUITEMENT le guide de sondes et trouvez la sonde qui correspond à vos besoins

Téléchargement

Description

Bandwidth DC to 70 MHz (-3 dB)
Attenuation Ratio x10 / x100
DC-Accuracy ±1 %
Input Impedance 4 MΩ, 5.5 pF each side to ground
Rise Time 5 ns
Measurement Category CAT III
Max. Amplitude ±7 V (into < 5 kΩ load)
Offset <±5 mV
Noise (typical) 2 mVrms
Source Impedance (typical) 50 Ω (for using 1 MΩ
input system oscilloscope)
CMRR (typical) -80 dB @ 50 Hz, -60 dB @ 20 kHz
-46 dB @ 1 MHz, -40 dB @ 10 MHz
Input Voltage
Differential Mode
x10 ±70 V (DC + peak AC)
or 70 Vrms
x100 ±700 V (DC + peak AC)
or 700 Vrms
Input Voltage
Common Mode
x10 ±700 V (DC + peak AC)
or 700 Vrms
x100 ±700 V (DC + peak AC)
or 700 Vrms
Input Voltage
Absolute max. Voltage
x10 ±1400 V (DC + peak AC)
or 1000 Vrms
x100 ±1400 V (DC + peak AC)
or 1000 Vrms
Power requirements 4x AA Cells or Mains Adaptor
6 VDC / 100 mA
or regulated9 VDC / 70 mA
Dimensions (L x W x H) 170 mm x 63 mm x 21 mm
Cable BNC Cable 95 cm
Input Leads 45 cm
Weight 400 g (Probe and PVC-Jacket included)

Fiche technique (peut contenir des options)

Atténuations 0 à 10 X, 100 à 250 X
Bandes passantes 50 à 150 MHz
Gammes de tension de crête 400 à 1 500 V
Système d'attache Ouvrant

30 autres produits dans la même catégorie

Principales Caractéristiques (Peut contenir des options)

Atténuations 100 à 250 X, 0 à 10 X
Bandes passantes 50 à 150 MHz
Gammes de tension de crête 400 à 1 500 V
Système d'attache Ouvrant
Close