Close
Condensateur Electrolytique Aluminium : Série KM Agrandir l'image

Condensateur Electrolytique Aluminium : Série KM | Capxon

Large plage de tension, jusqu'à 500 V

Plus de détails

Livre blanc : Supercondensateurs pour RTC Livre Blanc : Comparaison des condensateurs

Téléchargement

Description

Caractéristques techniques :

  • Endurance : 105°C ▪ 2 000 heures
  • Optimisé pour les applications rentables
  • Gamme de capacité élevée
  • Large plage de tension, jusqu'à 500 V

Spécifications :

Items   Performance Characteristics
Operating Temperature Range   -40 ~ +105°C -25 ~ +105°C
Rated Voltage Range VR 6.3 ~ 100V DC 160 ~ 500V DC
Surge Voltage VS (VR  ≤ 315V):      VS  = 1.15∙VR (VR  > 315V):     VS  = 1.10∙VR
Capacitance Range CR 0.1 ~ 22000µF 0.47 ~ 560µF
Cap. Tolerance ΔC ±20% (120Hz ▪ 20°C)
Leakage Current (20°C ▪ VR  applied) ILEAK ≤ 0.01∙CR∙VR  or 3µA, whichever is
greater ▪ After 1 minute
≤ 0.03∙CR∙VR  or 3µA, whichever is
greater ▪ After 1 minute
[ ILEAK  (µA) ; CR  (µF) ; VR  (V) ]
Dissipation Factor % (20°C ▪ 120Hz) tanδ VR  (V DC) 6.3 10 16 25   35 50 63 100
tanδ (%) 22 17 16 14   12 10 9 8
VR  (V DC) 160 200 250 350   400 420 450 500
tanδ (%) 12 12 12 15   15 17 17 22
For CR  ≥ 1000μF, add 2% per every multiple 1000μF of rated capacitance value                  
Low Temperature Characteristics at 120Hz Z ratio max. VR  (V DC) 6.3 10 16 25   35 50 63 100
Z-25°C/Z+20°C 4 3 2 2   2 2 2 2
Z-40°C/Z+20°C 8 6 4 3   3 3 3 3
VR  (V DC) 160 200 250 350   400 420 450 500
Z-25°C/Z+20°C 2 2 3 5   6 6 6 6
For capacitance > 1000µF
Z-25°C/Z+20°C Add 0.5 for every multiple 1000µF of rated capacitance value
Z-40°C/Z+20°C Add 1 for every multiple 1000µF of rated capacitance value
Lifetime Test
Endurance 105°C
(VR & IR  applied)
Test 2000 hours
△C/CR ≤ ±20% of initial measured value
tanδ ≤ 200% of initial specified value
ILeak ≤ the initial specified value
Test 1000 hours
Shelf Life 105°C (VR = 0) △C/CR ≤ ±20% of initial measured value
tanδ ≤ 200% of initial specified value
ILeak ≤ the initial specified value
Before measurement: Restore capacitor to 20°C, apply VR  for 30 min according JIS-C-5101-4

Conseils et Préconisations Composant Passif
Demarche commerciale
Expertise
Veille et Suivi
Agence en Chine

21 autres produits dans la même catégorie

Concevez votre borne de recharge avec ES France

Bornes de recharges

Close