Avec son testeur compact CT440, EXFO accélère les tests de précision des composants optiques passifs (MUX/DEMUX, filtres, séparateurs, etc.) et des modules (ROADM, WSS). Son domaine spectral de 1240 à 1680 nm couvre l’intégralité de la bande passante. L’option perte dépendante de la polarisation (PDL) permet de mesurer simultanément la perte d’insertion (IL).
Caractéristiques :
Applications :
SPECIFICATIONS | ||||||||||||||||||||
Model | F Full-band IL |
O O-band PM IL |
SCL SCL-bands PM IL |
PDL-O O-band IL & PDL |
PDL-SCL SCL-bands IL & PDL |
|||||||||||||||
Wavelength | Operating wavelength range (nm) | 1240 to 1680 | 1260 to 1360 | 1440 to 1640 | 1260 to 1360 | 1440 to 1640 | ||||||||||||||
Wavelength accuracy | Absolute (pm) a, b | ±5 | ||||||||||||||||||
Relative (pm) a | ±1 | ±5 | ||||||||||||||||||
Optical ports (front panel) | TLS inputs and outputs | Number of input ports | 1 to 4 (SMF) | 1 (PM13) | 1 (PM15) | 1 (PM13) | 1 (PM15) | |||||||||||||
Number of output ports | 1 (SMF) | 1 (PM13) | 1 (PM15) | 1 (SMF) | ||||||||||||||||
Connector type | FC/APC narrow key | |||||||||||||||||||
Polarization extinction ration (PER) | n/a | ≥20 dB | ≥18 dB (recommended) | |||||||||||||||||
Detector array | Number of detector ports | 1, 2 or 4 | ||||||||||||||||||
Connector type | FC/PC wide key | |||||||||||||||||||
Electrical ports (rear panel) |
Trigger out (5 V TTL) | Swept measurement external synchronization (pulse train generated at native sampling resolution) | ||||||||||||||||||
Trigger in (5 V TTL) | Triggered measurement without laser sweep control (measurement is taken when TTL level = high) | |||||||||||||||||||
Analog voltage in (0-5 V high impedance) | Voltage level sampling from an external device (sampling resolution of 1.3 mV) | |||||||||||||||||||
Optical power | Power range | On TLS input (dBm) | 0 to 10 | |||||||||||||||||
On detector ports (dBm) | –60 to 7 | |||||||||||||||||||
Transfer function | Accuracy (dB) c, d | ±0.2 | ||||||||||||||||||
Sampling resolution (dB) | 0.02 | |||||||||||||||||||
Dynamic range d, e | 65 dB typical for 1 or 2 TLS inputs 60 dB typical for 3 or 4 TLS inputs |
65 dB typical | ||||||||||||||||||
Polarization- dependent loss | Accuracy (dB) f | n/a | ±0.05 + 4% PDL | |||||||||||||||||
Measurement range g | n/a | 0 to 20 | ||||||||||||||||||
Repeatability | n/a | ±0.05 | ||||||||||||||||||
Sampling characteristics | Resolution (pm) | 1 to 250 | 5 to 250 | |||||||||||||||||
Native sampling resolution | N x 100 ±10 MHz (N=1 to 250) | |||||||||||||||||||
Compatible sweep speed of TLS (nm/s) | From 10 to 100 | |||||||||||||||||||
Data handling | Interface with PC / Data rate | USB-B 2.0 / 4 MBaud | ||||||||||||||||||
Maximum number of transfer function data points per TLS per detector as a function of number of activated detectors by software h | 260,000 for 1 detector 219,500 for 2 detectors 164,400 for 3 detectors 131,100 for 4 detectors 110,500 for 5 detectors |
|||||||||||||||||||
Environment | Temperature | Operating | 15 °C to 30 °C (59 °F to 86 °F) | |||||||||||||||||
Storage | –10 °C to 60 °C (14 °F to 140 °F) | |||||||||||||||||||
Relative humidity | < 80 % non-condensing | |||||||||||||||||||
Power supply | AC 100 V to 240 V (50 Hz to 60 Hz) | |||||||||||||||||||
Dimensions (W x H x D) | 440 mm x 50 mm x 375 mm (17.3 in x 2 in x 14.8 in), including rackmounting brackets | |||||||||||||||||||
Weight | Between 3.5 kg and 3.9 kg (7.7 lb to 8.6 lb), depending on model | |||||||||||||||||||
MEASUREMENT SETUP | ||||||||||||||||||||
Tunable laser source (TLS) | Remote control | GPIB | ||||||||||||||||||
Output power | See CT440 specifications above | |||||||||||||||||||
Sweep speed | See CT440 specifications above | |||||||||||||||||||
Mode hops | No mode hop is best but the instrument is able to detect and still operates with a few mode hops | |||||||||||||||||||
PC | Operating system | From Windows 7 to Windows 10 | ||||||||||||||||||
Interfaces | USB-A 2.0 port to CT440 and GPIB interface card to TLS |