NOS SERVICES
LA SOCIÉTÉ
INFORMATION
LOGICIELS | MATÉRIELS | SERVICES |
|
|||||||
|
NOTRE ACCOMPAGNEMENT ET NOTRE EXPERTISE | NOS VALEURS AJOUTEES |
NOS SOLUTIONS ET REALISATIONS |
|
|||||||
|
|
LIVRAISON
Attention : dernières pièces disponibles !
Nous vous contacterons pour valider votre commande quand le produit sera disponible.
Date de disponibilité :
La sonde portable qualité des eaux WQC-40 vous permet une mesure simultanée en standard des 9 paramètres suivants : pH, conductivité, turbidité, température, TDS, salinité totale eau de mer
Livré en standard avec les accessoires suivants :
Caractéristiques techniques des capteurs :
Items |
Measurement range |
Repeatability (Constant conditions) |
Measurement method |
pH | pH0.00 to pH14.00 | Within ±0.05pH | Glass electrode method |
Elctric conductivity(EC) | 0.00 to 10.00S/m | Within ±1%FS | AC 4-electrode method |
Display range:0.0 to 202.0mS/m, 0.000 to 2.020S/m, 0.00 to 20.20S/m(manual / automatic / switch range) | |||
SALT | 0.00 to 4.00%(NaCl) 0.00 to 40.00psu(PSS) |
Within NaCl:0.04% Within PSS:0.40psu |
Conversion from electrical conductivity |
Total dissolved solids (TDS) | 0.0 to 999.9g/L | Within ±1%FS | Conversion from electrical conductivity |
Sea water specific gravity(σt) | 0.0 to 50.0σt | Within ±0.5σt | Conversion from electrical conductivity |
Temperature (TEMP) | -5.00 to 55.00℃ | Within ±0.3℃ | Platinum resistor |
Turbidity (TURB)*1 |
0.0 to 80.0NTU(mg/L) 0 to 800NTU(mg/L) |
Within ±1.6NTU(0.0 to 80.0NTU) Within ±8NTU(0 to 800NTU) |
90 degree scattered light method |
Dissolved Oxygen(DO)(Optional) |
0.00 to 20.00mg/L 0 to 200% |
Within ±0.3mg/L Within ±4% |
Membrane galvanic cell method |
ORP(Optional) | -2000 to 2000mV | ― | Platinum electrode method |
Ion(Optional)*2(6 types:F-, Cl-, NO-, Ca2+, K+, NH+) |
0.00 to 2.00mg/L 0 to 62g/L(6 range) (Depending on electrode used) |
Within ±5mV | Ion electrode method |
Water depth (DEPT) (Factory option) | 0.0 to 100.0m | Within ±0.1m | Diaphragm pressure sensor method |
*1 Turbidity when calibrated with formazin standard solution is displayed as NTU, and turbidity when calibrated with kaolin standard solution is displayed as mg/L. (Suspended solids (SS) cannot be measured.) *2 Regarding ion measurement, it is a batch measurement |
Specifications techniques :
Instrument body |
|
Water proof structure | IP67(Immersion for 30 mins available for 1 m ) *Disabled when the sensor module is not connected and when using external input/output and USB |
USB(Peripheral, Micro) | Standard equipment (insulation) |
RS-232C | Standard equipment (external printer, RS-232C, GPS unit, shared with analog output, non-isolated) |
Analogue output | 100 to 2400 mV DC, up to 6 items can be set (isolated) |
Open collector output | Alarm output 2 points DC25V, 50mA or less (insulated) |
Performance guarantee temperature | 0 to 45℃ |
Power | 2 AA alkaline batteries / rechargeable Ni-MH batteries or USB power supply (no charging function) |
External dimensions (excluding protrusions) | Approx. 70(W)×39(H)×188(D)mm |
Weight (including batteries) | Approx. 300g |
Sensor module |
|
Water proof structure | Within 100m(1.0MPa)*The water depth when the ion electrode is attached is up to 5 to 15m depending on the type of electrode. |
RS-485(Modbus RTU) | Connectable with the optional Modbus power BOX |
Performance guarantee temperature | 0 to 45℃ |
Power | 3 AA alkaline batteries / rechargeable Ni-MH batteries |
External dimension (excluding protrusions) | Standard :Approx φ45×425(length)mm With water depth sensor :Approxφ47×500(length)mm |
Weight (including batteries) | Standard :Approx. 1330g With water depth sensor :Approx. 1470g |
Avantages :