Pompe seringue digitale à structure séparée, conçue pour un transfert et une manipulation précis de petits volumes de liquide.
Product model | Drive unit | dLSP 501S | dLSP 501L | dLSP 501W |
Controller | dLSP uC | |||
Work mode | Infusion only, withdrawal only, infusion/withdrawal, withdrawal/infusion, programming (on PC software) | |||
Display | 7 inch HD LCD | |||
Control mode | Touch screen controller | Control 1-4 separated drive units with preset parameters through touch screen controller | ||
Computer | Dedicated PC control software can control 10 drive units independently | |||
PLC/ other controller | RS485 interface, Modbus RTU, can control 40 drive units independently | |||
Stroke of the drive unit | 70mm | 95mm | ||
Pusher advance per microstep | 0.095um/ustep | 0.099um/ustep | 0.098um/ustep | |
Linear speed | 0.6096um/min-182.88mm/min | 0.635um/min-190.5mm/min | 0.625um/min-143.75mm/min | |
Linear speed resolution | 0.6096um/min | 0.635um/min | 0.625um/min | |
Linear travel accuracy | ≤±0.35%(when travel≥30% of the stroke) | |||
Linear travel CV | 0.03% (rated travel) | |||
Linear force (Rated) | 15N (the force can be set 20%-100%) | 30N (the force can be set 20%-100%) | 100N (the force can be set 20%-100%) | |
Syringe | 0.5uL-250uL | 0.5uL-1000uL | 0.5uL-60mL | |
Flow rate calibrate | Calibrate the user-defined syringe for better flow rate /dispensing volume accuracy and precision | |||
Parameter method | Up to 100 parameter methods can be stored on the controller and can be imported/exported to USB flash drive | |||
Programming function | Parameter configured based on work flow on PC software: infusion, withdrawal, delay, repeat, up to 16 steps | |||
Screen lock | Prevent misoperationg | |||
User access control | Three levels of user access (administrator, developer, operator), each user can have an exclusive password | |||
Log record | Record the pump operation history, and can be exported to a USB flash drive | |||
Electronic signature | There are electronic signature on the log record for FDA 21CFR Part11 compliance | |||
Pump state when power up | The default state is stop, can be set to continue to run through communication commands | |||
Fast forward/backward | Infuse or withdraw liquid at full speed | |||
Controller dimensions (L X W X H) | 187mm*123mm*39mm | |||
Controller weight | 0.6kg | |||
Power supply for controller | AC 90V-260V/30W | |||
Drive unit dimensions (L X W X H) | 170mm*35mm*58mm | 180mm*45mm*74mm | 235mm*103mm*91mm | |
Drive unit weight | 0.31kg | 0.51kg | 1.65kg | |
Power supply for drive unit | DC 24V/2W | DC 24V/3.6W | DC 24V/7.5W |
Product model | dLSP 501S | dLSP 501L | dLSP 501W | |
Syringe | Syringe ID(mm) | Flow rate for reference | ||
0.5uL | 0.0048nL/min-1.435uL/min | 0.0050nL/min-1.495uL/min | - | |
1uL | 0.15 | 0.0108nL/min-3.230uL/min | 0.0112nL/min-3.365uL/min | - |
2uL | 0.20 | 0.0191nL/min-5.742uL/min | 0.0199nL/min-5.982uL/min | - |
5uL | 0.35 | 0.0586nL/min-17.59uL/min | 0.0611nL/min-18.32uL/min | 0.0601nL/min-13.82uL/min |
10uL | 0.50 | 0.1196nL/min-35.89uL/min | 0.1246nL/min-37.39uL/min | 0.1227nL/min-28.21uL/min |
25uL | 0.80 | 0.3063nL/min-91.88uL/min | 0.3190nL/min-95.71uL/min | 0.3140nL/min-72.22uL/min |
50uL | 1.10 | 0.5790nL/min-173.7uL/min | 0.6032nL/min-180.9uL/min | 0.5937nL/min-136.5uL/min |
100uL | 1.46 | 1.020nL/min-306.0uL/min | 1.063nL/min-318.8uL/min | 1.046nL/min-240.5uL/min |
250uL | 2.30 | 2.531nL/min-759.4uL/min | 2.637nL/min-791.1uL/min | 2.595nL/min-596.9uL/min |
500uL | 3.25 | - | 5.265nL/min-1580uL/min | 5.182nL/min-1192uL/min |
1000uL | 4.61 | - | 10.594nL/min-3178uL/min | 10.43nL/min-2398uL/min |
2mL | 9.00 | - | - | 39.74nL/min-9.140mL/min |
5mL | 13.10 | - | - | 84.20nL/min-19.37mL/min |
10mL | 16.60 | - | - | 135.2nL/min-31.10mL/min |
20mL | 19.00 | - | - | 177.1nL/min-40.74mL/min |
30mL | 23.00 | - | - | 259.5nL/min-59.69mL/min |
60mL | 29.14 | - | - | 416.6nL/min-95.82mL/min |
La filtration est communément l'opération mécanique ou physique utilisée pour la séparation des solides des fluides (liquides ou gaz) en interposant un milieu à travers lequel seul le fluide peut passer. Le fluide qui passe à travers est appelé le filtrat.
La filtration est généralement l'opération mécanique ou physique utilisée pour la séparation des solides des fluides (liquides ou gaz) en interposant un milieu à travers lequel seul le fluide peut passer. Le fluide qui passe à travers est appelé le filtrat.
Le système de filtration complet comprend généralement : un réservoir pour le fluide, une pompe pour transférer le fluide, un manomètre pour contrôler la pression et un filtre pour la filtration. La plupart des clients choisissent une pompe péristaltique comme pompe de transfert de fluide. Cela s'explique par la faible force de cisaillement de la pompe péristaltique, qui protège le fluide pendant le transfert. De plus, il est facile de changer les tubes pour transférer différents fluides.